مقاله Assessment and Elimination of Errors due to Electrode Disp

 

برای دریافت پروژه اینجا کلیک کنید

مقاله Assessment and Elimination of Errors due to Electrode Displacements in Elliptical and Square Models in EIT فایل ورد (word) دارای 7 صفحه می باشد و دارای تنظیمات در microsoft word می باشد و آماده پرینت یا چاپ است

فایل ورد مقاله Assessment and Elimination of Errors due to Electrode Displacements in Elliptical and Square Models in EIT فایل ورد (word) کاملا فرمت بندی و تنظیم شده در استاندارد دانشگاه و مراکز دولتی می باشد.

این پروژه توسط مرکز مرکز پروژه های دانشجویی آماده و تنظیم شده است

توجه : در صورت  مشاهده  بهم ریختگی احتمالی در متون زیر ،دلیل ان کپی کردن این مطالب از داخل فایل ورد می باشد و در فایل اصلی مقاله Assessment and Elimination of Errors due to Electrode Displacements in Elliptical and Square Models in EIT فایل ورد (word) ،به هیچ وجه بهم ریختگی وجود ندارد


بخشی از متن مقاله Assessment and Elimination of Errors due to Electrode Displacements in Elliptical and Square Models in EIT فایل ورد (word) :

سال انتشار: 1389

محل انتشار: ششمین کنفرانس ماشین بینایی و پردازش تصویر

تعداد صفحات: 7

نویسنده(ها):

Ashkan Javaherian – Department of Nuclear Engineering, Shiraz University
Amir Movafeghi – Atomic Energy Organization, Nuclear Science and Technology Center
Reza Faghihi – Head of Depatrment of Nuclear Engineering, Shiraz university

چکیده:

This study modifies a Tikhonov regularized "maximum a posteriori" algorithm proposed for reconstructing both the conductivity changes and electrode positioning variations in EIT and uses this algorithm for reconstructing images of 2d elliptical and square models , instead of simple circular model used in previous works. This algorithm had been proposed By C.Gomez for compensating the errors due to electrode movements in image reconstruction. The jacobian matrix has been constructed via perturbation both conductivity and electrode positioning. The prior image matrix should incorporate some kind of augmented inter-electrode positioning correlations to impose a smoothness constraint on both the conductivity change distribution and electrode movement. For each model, conductivity change image is reconstructed in 3 cases: a) With no electrode displacement using standard algorithm b) With electrode displacement using standard algorithm c) With electrode displacement using proposed algorithm In all models, a comparison between 3 cases has been implemented. Also, the results obtained from each model have been compared with the other models in similar cases. The results obtained in this study will be useful to investigate the ellipticity effects of organs being imaged in clinical applications. Moreover, the effects of model deviation from circular form on reconstructed images can be used in special industrial applications.

 

 

برای دریافت پروژه اینجا کلیک کنید
» نظر